About Us
Author Guidelines
Contact Us
Supplier Info
 


Current Issue
Sample issue of JATCurrent Issue


Contact Info:
6600 W. Touhy Ave.
Niles, IL 60714
Tel: 847.647.2900
Fax: 847.647.1155
circulation@jatox.com

 

 
   

Journal of Analytical Toxicology Article Abstracts

Journal of Analytical Toxicology Horizontal Line

Published: Journal of Analytical Toxicology, ISSN 0146-4760, Volume 31, Number 1, January/February 2007, pp.23-30

Comparison of Hospital Laboratory Serum Alcohol Levels Obtained by an Enzymatic Method with Whole Blood Levels Forensically Determined by Gas Chromatography
Matthew T. Barnhill, Jr[1], Donald Herbert[2], David J. Wells, Jr.[3]
[1]110 Oak Street, Fairhope, Alabama 36532
[2]University of South Alabama College of Medicine, Department of Radiology, 2451 Fillingim Street, Mobile, Alabama 36617
[3]Mission Pharmacal Laboratory, 1325 E. Durango, San Antonio, Texas 78210

Estimating the equivalent whole blood ethanol level from a serum or plasma determination has been addressed by numerous articles in both the clinical and forensic literature. All previous studies have either involved sample sizes insufficient for adequate statistical evaluation or have utilized gas chromatography for both serum and whole blood analysis. In this study, based on samples from 212 consecutive patients admitted to a hospital trauma center, serum was assayed for ethanol using an enzymatic oxidation method, and the results were compared to whole blood samples taken simultaneously and analyzed by headspace gas chromatography in a forensic toxicology laboratory. Contrary to previously published conclusions, it was found that the serum/whole blood alcohol ratio (SAC/BAC) is concentration-dependent, with average values ranging from around 1.12 to as high as around 1.18, depending on SAC, thus precluding a generally applicable SAC/BAC conversion factor. However, a linear regression model was found to provide adequate prediction intervals at any desired level of confidence for whole blood alcohol from serum alcohol levels up to 300 mg/dL. For example, at a confidence level of 95%, an SAC of 103 mg/dL corresponds to a BAC of at least 0.080 g/dL.

Reproduction of editorial content of this journal is prohibited without publisher’s permission.

This article is available in its entirety by fax for $4.00 per page.
Visa or MasterCard accepted.

To order electronically click here
or call: 847-647-2900 ext. 1323
or fax request to: 847-647-1155.

Please indicate JAT volume and issue along with page numbers.


| Home | Subscribe | Current Issue | Back Issues | Search | Advertise | Other Publications |