Published: Journal of Analytical Toxicology, ISSN 0146-4760, Volume 26, Number 6, September 2002, pp. 360-364

TECHNICAL NOTE: Determination of Cobalt in Urine by FI-ICP-AES with Online Preconcentration
Gustavo M. Farias[1], Rodolfo G. Wuilloud[1], Susana Moyano[1], José A. Gásquez1, Roberto A. Olsina[1],[2], and Luis D. Martinez[1],[2]
[1]Department of Analytical Chemistry, Faculty of Chemistry, Biochemistry and Pharmacy, National University of San Luis, P.O. Box 375, 5700 San Luis, Argentina and
[2]Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Rivadavia 1917, CP C1033 AAJ, Cuidad de Buenos Aires, Argentina

A method for the preconcentration and determination of cobalt in human urine samples was developed. The online preconcentration and determination were attained using inductively coupled plasma atomic emission spectromety (ICP-AES) coupled to a flow injection (FI) method. Cobalt was retained on an Amberlite XAD-7 resin as cobalt-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex at pH 9.5. Cobalt was removed from the microcolumn with perchloric acid. A sensitivity enhancement factor of 90 was obtained with respect to cobalt determination by ICP-AES without preconcentration. The value of detection limit for the preconcentration method proposed was 25 ng/L. The precision for 10 replicate determinations at the 5 mg/L (mean ± SD, 5.1 ± 0.14) Co level was 2.7% relative standard deviation, calculated from the peak heights obtained. The calibration graph preconcentration method for cobalt was linear with a correlation coefficient of 0.9994 from approximately 0.25 mg/L up to at least 100 mg/L. The method was successfully applied to the determination of cobalt in human urine samples.

Reproduction of editorial content of this journal is prohibited without publisher’s permission.

This article is available in its entirety by fax for $40.00 each.
Visa, MasterCard and AMEX accepted.

To order electronically click here
or call: 847-647-2900 ext. 1323
or fax request to: 847-647-1155.

To order multiple copies click here.

Please indicate JAT volume and issue along with page numbers.


| Home | Subscribe | Current Issue | Back Issues | Search | Advertise | Other Publications |