![]()
![]()
Published: Journal of Analytical Toxicology, Volume 24, Number 2, March, pp.146-152
Determination of b2-Agonists
in Bovine Urine: Comparison of Two Extraction/Clean-Up Procedures for High-Resolution
Gas Chromatography Mass Spectrometry Analysis
1Instituto Nacional
de Controle de Qualidade em Saúde (INCQS), Fundação Oswaldo
Cruz, Av. Brasil, 4365, Rio de Janeiro, Brazil; 2Departamento de Química
Analítica; and 3Departamento de Química Orgânica, Instituto
de Química, Ilha do Fundão, CT, Bl. A, 21949-900, Universidade
Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, Brazil
Two extraction/clean-up analytical procedures were investigated and compared regarding their recovery and matrix-purification efficiency for screening b2-agonist residues in fortified bovine urine by high-resolution gas chromatographymass spectrometry (GCMS). The first procedure, based on an analytical method originally developed for detecting anabolic steroids, consists of the employment of the nonionic resin, Amberlite® XAD-2, a styrene-divinylbenzene copolymer for solid-phase extraction (SPE), followed by liquidliquid extraction with diethyl ether. The second focuses on the use of a mixed SPE cartridge (reversed-phase and ion-exchange sorbent, Bond Elut Certify®). In both cases, the trimethylsilylated derivatives were analyzed by GCMS with an ion-trap detector. Clenbuterol, salbutamol, and terbutaline were used to spike urine samples during the comparison experimental phase. Afterwards, tulobuterol, mabuterol, mapenterol, cimbuterol, and brombuterol were included in the evaluation of the second procedure (the Bond Elut Certify procedure). At this stage, the detection was accomplished by GCMS (quadrupole mass analyzer) with selective ion monitoring acquisition. The isotopic dilution method with the hexadeuterated analogues of clenbuterol and salbutamol was applied to prepare calibration curves and calculate recovery percentages. With XAD-2 resin, terbutaline and salbutamol (resorcinol and phenol-type b2-agonists, respectively) could not be detected at 20 ng/mL or at 40 ng/mL. In spite of clenbuterol having been detected at 20 ng/mL, the results obtained were not reproducible. The use of the reversed-phase and ion-exchange sorbent Bond Elut Certify allowed multiresidue detection and showed several advantages for the screening of clenbuterol such as higher recoveries, cleaner final extracts, reduced sample preparation time, less labor intensive, and easier solvent consumption and disposal. Recoveries over 88% (concentrations ranging from 0.5 to 10 ppb) and limits of detection equal to 0.5 ppb were met for all the b2-agonists studied with the last method.
Reproduction of editorial content of this journal is prohibited without publishers permission.
| This article is available in its entirety by fax for $4.00 per page. Visa or MasterCard accepted. To order electronically click
here Please indicate JAT volume and issue along with page numbers. |
| Home | Subscribe | Current Issue | Back Issues | Search | Advertise | Other Publications | Site Map |