![]()
![]()
Published: Journal of Analytical Toxicology, Volume 23, Number 7, Nov/Dec 1999, pp. 603-608
A Gas ChromatographyMass Spectrometry Method for
the Quantitation of Clobenzorex
J
Recent studies have demonstrated the utility of quantitative assays for benzoylecgonine in assessing the efficacy of cocaine-dependence-Drugs metabolized to amphetamine or methamphetamine are potentially significant concerns in the interpretation of amphetamine-positive urine drug-testing results. One of these compounds, clobenzorex, is an anorectic drug that is available in many countries. Clobenzorex (2-chlorobenzylamphetamine) is metabolized to amphetamine by the body and excreted in the urine. Following administration, the parent compound was detectable for a shorter time than the metabolite amphetamine, which could be detected for days. Because of the potential complication posed to the interpretation of amphetamine-positive drug tests following administration of this drug, the viability of a current amphetamine procedure using liquidliquid extraction and conversion to the heptafluorobutyryl derivative followed by gas chromatographymass spectrometry (GCMS) analysis was evaluated for identification and quantitation of clobenzorex. Qualitative identification of the drug was relatively straightforward. Quantitative analysis proved to be a far more challenging process. Several compounds were evaluated for use as the internal standard in this method, including methamphetamine-d11, fenfluramine, benzphetamine, and diphenylamine. Results using these compounds proved to be less than satisfactory because of poor reproducibility of the quantitative values. Because of its similar chromatographic properties to the parent drug, the compound 3-chlorobenzylamphetamine (3-Cl-clobenzorex) was evaluated in this study as the internal standard for the quantitation of clobenzorex. Precision studies showed 3-Cl-clobenzorex to produce accurate and reliable quantitative results (within-run relative standard deviations [RSDs] < 6.1%, between-run RSDs < 6.0%). The limits of detection and quantitation for this assay were determined to be 1 ng/mL for clobenzorex.
Reproduction of editorial content of this journal is prohibited without publishers permission.
| This article is available in its entirety by fax for $40.00 each. Visa, MasterCard and AMEX accepted. To order electronically click
here Please indicate JAT volume and issue along with page numbers. |
| Home | Subscribe | Current Issue | Back Issues | Search | Advertise | Other Publications | Site Map |